Instrument:

Ordering code structure: 7846 – A – B – C – D – E – F – L – M – NNNNN – P / X
Please select the required options from tables A, B… below to define the right device reference.
7846                 GreenLine 6000
Standard delivery includes:
  • Base unit with 2 sensors (O+ CO)
  • Li-ION battery + charger module
  • Internal impact printer
  • 1,000 data memory & real time clock
  • Configuration software GasConfig
  • Data management software DBGas2004 Lite version
  • USB adapter
  • Draft and differential pressure measurement
  • Remote module with 2.5 m long shielded cable
  • Factory test report
  • Instruction manual
  • Warranty: 1 year
OR
7846WL            GreenLine 6000 Wireless (Bluetooth MCU/RCU)

Table A – SENSOR No. 1
1                      O2 (0 - 25%)
Table B – SENSOR No. 2
2H                    CO (0 - 8,000 ppm) H2 compensated + Dilution system
2X                     CO (0 - 20,000 ppm)
2LO                  CO (0 - 500 ppm / res. 0.1 ppm) + Dilution system
Table C – SENSOR No. 3
0                      None
4                      NO (0 - 4,000 ppm / res. 1 ppm) & NOx calculation
4LO                 NO (0 - 500 ppm / res. 0.1 ppm) & NOx calculation
Table D – SENSOR No. 4
0                      None
5                      NO2 (0 - 1,000 ppm)
5LO                  NO2 (0 - 100 ppm)
8                      CxHy (0 - 5%)
Table E – SENSOR No. 5
0                      None
6                      SO2 (0 - 4,000 ppm)
8                      CxHy (0 - 5%)
Table F – SENSOR No. 6
0                      None
7                      CO% (0 - 10%)
8                      CxHy (0 - 5%)
9                      H2S (0 - 1,000 ppm)
Table L – Sample probes
0                      None                                                                                    
1                      Ø8 / 300 mm gas + draft probe (dual hose)
2P                    Ø10 / 750 mm gas + draft probe (dual hose) removable tip         
3P                    Ø10 / 1500 mm gas + draft probe (dual hose) removable tip
2SP                  Ø10 / 750 mm heated* gas + draft probe (dual hose) removable tip
3SP                  Ø10 / 1500 mm heated* gas + draft probe (dual hose) removable tip
F10                   Sintered filter for 2, 3, S & P probes Ø10 mm 
* Heated gas probe used for smoke index measurement.
Table M – Mains adapter / Charger
1                      115 V (50/60 Hz) – USA plug
2                      230 V (50/60 Hz) – Schuko plug
3                      230 V (50/60 Hz) – UK plug
4                      230 V (50/60 Hz) – European plug
5                      100 V (50/60 Hz) – USA / Japan plug
Table N – Accessories
0                      None
1                      DBGas 2004 standard software
2                      300 mm Pitot tube
3                      750 mm Pitot tube
4                      Pt100 remote combustion air temperature probe, length: 2 m
Table P – Calibration certificate
1                      Factory certificate (gas + pressure + temperature)
Table X – Customization
INTL                 English language - manual in English - English keyboard
USA                  English language - manual in English - English keyboard
FR                    French language - manual in French - French keyboard
HOL                  Dutch language - manual in English - English keyboard
POL                  Polish language - manual in English - English keyboard
SPA                  Spanish language - manual in English - English keyboard
UK                    English language - manual in English - English keyboard

Accessories:

Probes and sensors:
BB830006          Pt100 remote air sensor + positioning cone (with 2 m cable)
BB830025          External probe for natural boiler draft (200 Pa)
BB610032          Pitot tube 300 mm
BB610033          Pitot tube 800 mm
BB610034          Pitot tube 1000 mm
EE610106          Ø8 / 300 mm tip (max. 800°C)
EE610105          Ø8 / 750 mm tip (max. 800°C)
EE610015          Ø8 / 1000 mm tip (max. 800°C)
EE610104          Ø8 / 1500 mm tip (max. 800°C)
EE610098          Ø10 / 300 mm tip (P option)
EE610102          Ø10 / 750 mm tip (P option)
EE610029          Ø10 / 1000 mm tip (P or SP option)
EE610100          Ø10 / 1500 mm tip (P option)
BB610058          Ø8 / 300 mm gas or draft probe (dual hose)
BB610066          Ø10 / 750 mm gas + draft probe (dual hose) removable tip
BB610067          Ø10 / 1500 mm gas + draft probe (dual hose) removable tip        
BB610068          Ø10 / 750 mm heated gas + draft probe (dual hose) removable tip
BB610069          Ø10 / 1500 mm heated gas + draft probe (dual hose) removable tip
F2132100          130 mm air TC K-type probe
F2137100          130 mm contact TC K-type probe
F2139000          Pipe Velcro TC K-type probe
Consult us         3 m extension for dual hose probe and Tc
Consult us         6 m extension for dual hose probe and Tc 
Test tools and miscellaneous:
EE300088          Single hose pressure probe and burner hose kit
EE300248          Kit for detecting leaks in gas networks (pump + hose + adapters)
F7828000          Manual pump for smoke index measurements + 40 filters + table
Software and connectors:
BB260166          DBGas 2004 standard software
Consumable parts:
EE340005          Printer paper roll - Minimum order of 10 pcs
EE490002          Printer ribbon - Minimum order of 3 pcs
EE650072          Line and autozero filter cartridge - Minimum order of 10 pcs
EE650073          NOx / SOx filter cartridge - Minimum order of 10 pcs
EE650074          Filter cartridge for EE650076 / EE 650082 water trap + filter - Minimum order of 10 pcs
EE650091          Quartz filter for heated head probe - Minimum order of 3 pcs
EE650099          Sintered filter for Ø10 mm tip
EE650100          Sintered filter for Ø8 mm tip

Packing information:

Size:                    Main Control Unit: 455 x 205 x 365 mm
                            Hand-Held Remote Control Unit: 115 x 90 x 330 mm
Weight:                Main Control Unit: 10 kg
                            Hand-Held Remote Control Unit: 0.9 kg
ProductDescriptionReleaseTypeDBGas 2004
Instruction manual
MM850523-K12DBGas 2004
Data management software under Windows©
4.0.18zipGasConfig
Configuration software under Windows©
2.0.22zipGreenLine 6000-8000
Instruction manual
MM850371-K12pdf